Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Science ; 372(6546): 1081-1085, 2021 06 04.
Artigo em Inglês | MEDLINE | ID: mdl-34083487

RESUMO

Gamma-ray bursts (GRBs), which are bright flashes of gamma rays from extragalactic sources followed by fading afterglow emission, are associated with stellar core collapse events. We report the detection of very-high-energy (VHE) gamma rays from the afterglow of GRB 190829A, between 4 and 56 hours after the trigger, using the High Energy Stereoscopic System (H.E.S.S.). The low luminosity and redshift of GRB 190829A reduce both internal and external absorption, allowing determination of its intrinsic energy spectrum. Between energies of 0.18 and 3.3 tera-electron volts, this spectrum is described by a power law with photon index of 2.07 ± 0.09, similar to the x-ray spectrum. The x-ray and VHE gamma-ray light curves also show similar decay profiles. These similar characteristics in the x-ray and gamma-ray bands challenge GRB afterglow emission scenarios.

2.
Nature ; 575(7783): 464-467, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31748724

RESUMO

Gamma-ray bursts (GRBs) are brief flashes of γ-rays and are considered to be the most energetic explosive phenomena in the Universe1. The emission from GRBs comprises a short (typically tens of seconds) and bright prompt emission, followed by a much longer afterglow phase. During the afterglow phase, the shocked outflow-produced by the interaction between the ejected matter and the circumburst medium-slows down, and a gradual decrease in brightness is observed2. GRBs typically emit most of their energy via γ-rays with energies in the kiloelectronvolt-to-megaelectronvolt range, but a few photons with energies of tens of gigaelectronvolts have been detected by space-based instruments3. However, the origins of such high-energy (above one gigaelectronvolt) photons and the presence of very-high-energy (more than 100 gigaelectronvolts) emission have remained elusive4. Here we report observations of very-high-energy emission in the bright GRB 180720B deep in the GRB afterglow-ten hours after the end of the prompt emission phase, when the X-ray flux had already decayed by four orders of magnitude. Two possible explanations exist for the observed radiation: inverse Compton emission and synchrotron emission of ultrarelativistic electrons. Our observations show that the energy fluxes in the X-ray and γ-ray range and their photon indices remain comparable to each other throughout the afterglow. This discovery places distinct constraints on the GRB environment for both emission mechanisms, with the inverse Compton explanation alleviating the particle energy requirements for the emission observed at late times. The late timing of this detection has consequences for the future observations of GRBs at the highest energies.

3.
Phys Rev Lett ; 120(20): 201101, 2018 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-29864326

RESUMO

Spectral lines are among the most powerful signatures for dark matter (DM) annihilation searches in very-high-energy γ rays. The central region of the Milky Way halo is one of the most promising targets given its large amount of DM and proximity to Earth. We report on a search for a monoenergetic spectral line from self-annihilations of DM particles in the energy range from 300 GeV to 70 TeV using a two-dimensional maximum likelihood method taking advantage of both the spectral and spatial features of the signal versus background. The analysis makes use of Galactic center observations accumulated over ten years (2004-2014) with the H.E.S.S. array of ground-based Cherenkov telescopes. No significant γ-ray excess above the background is found. We derive upper limits on the annihilation cross section ⟨σv⟩ for monoenergetic DM lines at the level of 4×10^{-28} cm^{3} s^{-1} at 1 TeV, assuming an Einasto DM profile for the Milky Way halo. For a DM mass of 1 TeV, they improve over the previous ones by a factor of 6. The present constraints are the strongest obtained so far for DM particles in the mass range 300 GeV-70 TeV. Ground-based γ-ray observations have reached sufficient sensitivity to explore relevant velocity-averaged cross sections for DM annihilation into two γ-ray photons at the level expected from the thermal relic density for TeV DM particles.

4.
Phys Rev Lett ; 119(11): 112002, 2017 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-28949229

RESUMO

The first measurement of transverse-spin-dependent azimuthal asymmetries in the pion-induced Drell-Yan (DY) process is reported. We use the CERN SPS 190 GeV/c π^{-} beam and a transversely polarized ammonia target. Three azimuthal asymmetries giving access to different transverse-momentum-dependent (TMD) parton distribution functions (PDFs) are extracted using dimuon events with invariant mass between 4.3 GeV/c^{2} and 8.5 GeV/c^{2}. Within the experimental uncertainties, the observed sign of the Sivers asymmetry is found to be consistent with the fundamental prediction of quantum chromodynamics (QCD) that the Sivers TMD PDFs extracted from DY have a sign opposite to the one extracted from semi-inclusive deep-inelastic scattering (SIDIS) data. We present two other asymmetries originating from the pion Boer-Mulders TMD PDFs convoluted with either the nucleon transversity or pretzelosity TMD PDFs. A recent COMPASS SIDIS measurement was obtained at a hard scale comparable to that of these DY results. This opens the way for possible tests of fundamental QCD universality predictions.

5.
Nano Lett ; 16(6): 3415-25, 2016 06 08.
Artigo em Inglês | MEDLINE | ID: mdl-27187840

RESUMO

Vertically aligned hexagonal InN nanorods were grown mask-free by conventional metal-organic vapor phase epitaxy without any foreign catalyst. The In droplets on top of the nanorods indicate a self-catalytic vapor-liquid-solid growth mode. A systematic study on important growth parameters has been carried out for the optimization of nanorod morphology. The nanorod N-polarity, induced by high temperature nitridation of the sapphire substrate, is necessary to achieve vertical growth. Hydrogen, usually inapplicable during InN growth due to formation of metallic indium, and silane are needed to enhance the aspect ratio and to reduce parasitic deposition beside the nanorods on the sapphire surface. The results reveal many similarities between InN and GaN nanorod growth showing that the process despite the large difference in growth temperature is similar. Transmission electron microscopy, spatially resolved energy-dispersive X-ray spectroscopy, X-ray diffraction, X-ray photoelectron spectroscopy, and Raman spectroscopy have been performed to analyze the structural properties. Spatially resolved cathodoluminescence investigations are carried out to verify the optical activity of the InN nanorods. The InN nanorods are expected to be the material of choice for high-efficiency hot carrier solar cells.

6.
Phys Rev Lett ; 115(8): 082001, 2015 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-26340182

RESUMO

The COMPASS Collaboration at CERN has measured diffractive dissociation of 190 GeV/c pions into the π(-)π(-)π(+) final state using a stationary hydrogen target. A partial-wave analysis (PWA) was performed in bins of 3π mass and four-momentum transfer using the isobar model and the so far largest PWA model consisting of 88 waves. A narrow peak is observed in the f0(980)π channel with spin, parity and C-parity quantum numbers J(PC)=1(++). We present a resonance-model study of a subset of the spin-density matrix selecting 3π states with J(PC)=2(++) and 4(++) decaying into ρ(770)π and with J(PC)=1(++) decaying into f0(980)π. We identify a new a1 meson with mass (1414(-13)(+15)) MeV/c2 and width (153(-23)(+8)) MeV/c2. Within the final states investigated in our analysis, we observe the new a1(1420) decaying only into f0(980)π, suggesting its exotic nature.

7.
Phys Rev Lett ; 114(6): 062002, 2015 Feb 13.
Artigo em Inglês | MEDLINE | ID: mdl-25723208

RESUMO

The COMPASS collaboration at CERN has investigated pion Compton scattering, π(-)γ→π(-)γ, at center-of-mass energy below 3.5 pion masses. The process is embedded in the reaction π(-)Ni→π(-)γNi, which is initiated by 190 GeV pions impinging on a nickel target. The exchange of quasireal photons is selected by isolating the sharp Coulomb peak observed at smallest momentum transfers, Q(2)<0.0015 (GeV/c)(2). From a sample of 63,000 events, the pion electric polarizability is determined to be α(π)=(2.0±0.6(stat)±0.7(syst))×10(-4) fm(3) under the assumption α(π)=-ß(π), which relates the electric and magnetic dipole polarizabilities. It is the most precise measurement of this fundamental low-energy parameter of strong interaction that has been addressed since long by various methods with conflicting outcomes. While this result is in tension with previous dedicated measurements, it is found in agreement with the expectation from chiral perturbation theory. An additional measurement replacing pions by muons, for which the cross-section behavior is unambiguously known, was performed for an independent estimate of the systematic uncertainty.

8.
Acta Orthop Scand ; 68(3): 225-30, 1997 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-9246981

RESUMO

40 patients undergoing primary hip arthroplasty, given autologous processed blood transfusion, were randomized a receive no antibiotic prophylaxis (group A, n 20) or cefuroxime (1.5 g single injection; group B, n 20). Bacterial contamination at various steps in the autotransfusion procedure was assessed in liquid and solid culture media. The operation field and the wound drainage blood were never contaminated either of the groups but some of the suction tips were. Parts of the Vacufix blood collection bags of group A contained bacteria, but none in group B. Processed red blood cell concentrates in both groups showed bacterial growth. Greater blood loss did not increase the contamination rate in general. Isolated bacteria included the species Staphylococcus epidermidis, coagulase-negative staphylococci and Propionibacteria in both groups, but with different cell counts. In addition, Corynebacterium bovis et minutissimum and Moraxelle were identified in group A. In conclusion, autologous blood transfusion was a safe procedure. If contamination occurred, the bacterial count was low, and the bacteria of low pathogenicity. Antibiotic prophylaxis with cefuroxime reduced this contamination of suction tips and collection bags and limited the transfer of autologous blood products.


Assuntos
Antibioticoprofilaxia/métodos , Transfusão de Sangue Autóloga/efeitos adversos , Cefuroxima/uso terapêutico , Cefalosporinas/uso terapêutico , Prótese de Quadril/métodos , Infecção da Ferida Cirúrgica/prevenção & controle , Bactérias/isolamento & purificação , Infecções Bacterianas/sangue , Infecções Bacterianas/etiologia , Infecções Bacterianas/prevenção & controle , Perda Sanguínea Cirúrgica/prevenção & controle , Transfusão de Sangue Autóloga/instrumentação , Contaminação de Equipamentos , Contagem de Eritrócitos , Feminino , Humanos , Contagem de Leucócitos , Masculino , Pessoa de Meia-Idade , Fatores de Risco , Segurança , Infecção da Ferida Cirúrgica/sangue , Infecção da Ferida Cirúrgica/microbiologia
9.
Artigo em Inglês | MEDLINE | ID: mdl-8865946

RESUMO

MATERIALS AND METHODS: In a prospective randomized study we investigated the effect of hemodilution on cefuroxime levels and bacterial contamination of processed shed blood during hip arthroplasty. 10 patients received cefuroxime 1,5 g as single shot prophylaxis before (group A), 10 after hemodilution (15 ml/KG) (group B). Cefuroxime levels in serum 1 h after administration, at the end of operation, after 12 h and in drainage-blood after 12 h were assessed by HPLC. Bacteriological study was performed from collecting bags (Vacufix), wound drainage blood and processed red blood cell concentrates, using pour plate technique and broth culture enrichment. RESULTS AND DISCUSSION: Mean concentrations of cefuroxime were higher in group B than group A, but differed not significantly. No bacterial contamination was found in collecting bags and wound drainages in both groups. Processed red cell concentrates in group B showed no growth. In group A, however, 3/10 were contaminated with < or = CFU/ml of coagulase-negative Staphylococcus, Staphylococcus epidermidis and Propionibacterium acnes. The differences between groups did not reach the level of statistical significance and could not be related to lower cefuroxime levels. No wound infection occurred in either group.


Assuntos
Antibioticoprofilaxia , Transfusão de Sangue Autóloga , Sangue/microbiologia , Cefuroxima/farmacocinética , Hemodiluição , Prótese de Quadril , Cefuroxima/administração & dosagem , Contagem de Colônia Microbiana , Esquema de Medicação , Humanos , Estudos Prospectivos
10.
Physiotherapy ; 65(6): 189-90, 1979 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-523565
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...